A process plant and an enterprise office with servers, side by side, joined by one line of light

Stream Gateway OT/IT Integration Platform

Trusted by

  • Aramco
  • SABIC
  • Saudi Electricity Company
  • Dubai Electricity and Water Authority
  • Emaar
  • National Water Company
  • Modon
  • Qiddiya
  • MiSK Foundation
  • solutions by stc
  • Mondelez International
  • Hunter
  • Giza Systems
  • Khalda Petroleum Company
  • Egyptian Electricity Transmission Company
  • Cairo Water Company

OT/IT Integration Done Right

Operational Technology

Plant floor and field

  • PLCs and controllers

    Modbus · Siemens S7 · Allen-Bradley

  • SCADA and DCS

    OPC DA · OPC UA

  • Substations and IEDs

    IEC 61850 · IEC 60870-5-104 · DNP3

  • Meters and RTUs

    Modbus · DNP3 · IEC 60870-5-101

  • IIoT and Cloud

    MQTTs · APIs · Azure · AWS

Stream Gateway

Unified data layer

  • Every source connected once
  • One model: tags and Digital Blocks
  • Asset hierarchy, quality and time
  • History, alarms, store and forward

Information Technology

Enterprise and cloud

  • ERP and MES

    REST API · web services

  • Databases and historians

    SQL · Postgres · Oracle - Plugins

  • Cloud platforms

    MQTT · AWS · Azure · Google Cloud

  • Analytics and AI

    Kafka · REST API

  • SCADA and OPC

    OPC UA server

Digital Blocks

Every asset becomes a live model.

Measured, calculated and AI-derived values on one Digital Block, for every transformer, pump and meter on site.

Stream Platform asset view of a transformer: live bus voltage, current, oil and winding temperatures, load and tap position, beside its digital twin with running hours, alarm count, overall health and anomaly detection
Stream Platform asset view of a pump station: live flow, suction and discharge pressure and motor temperature, beside its digital twin with running hours, alarm count, overall health and anomaly detection
A Digital Block from Stream Gateway, shown in the Stream Platform asset view.
  • Measured values from the device
  • Calculated health and running hours
  • AI-derived anomaly detection

Model · Transform · Contextualize

From raw tags to an asset in context.

Five protocols become one Digital Block, in engineering units, placed in your asset hierarchy.

Raw data

Scattered data sources

  • Protection relayIEC 61850
    MMXU1.A.phsA = 412.0 YLTC1.TapPos = 5
  • PLCModbus TCP
    40021 = 653
  • Online monitorOPC UA
    HotSpot = 78.1
  • Gas sensorMQTT
    {"h2_ppm": 120}
  • Maintenance systemREST API
    {"last_service": "2026-03-14"}

Transformer TR-03

Digital Block: Transformer

  • Load current412.0 AIEC 61850
  • Tap position5IEC 61850
  • Oil temperature65.3 °CModbus
  • Hot-spot78.1 °COPC UA
  • Hydrogen (H₂)120 ppmMQTT
  • Last service14 Mar 2026REST
  • Load factor78 %calculated
  • Health index88 %calculated
  • AnomalyDetectedAI

In context

ISA-95 or your own hierarchy

  • SiteSite 1
  • AreaSubstation A
  • AssetTR-01
  • AssetTR-02
  • AssetTR-03
  • AreaSubstation B
  • AssetTR-04

Every transformer is an instance of the block: edit it once, and all of them follow.

Raw data

Scattered data sources

  • Pressure RTUIEC 104
    IOA 2001 = 3.76 IOA 2002 = 9.48
  • Drive (VSD)Modbus TCP
    40105 = 950
  • Station PLCSiemens S7
    DB10.DBD4 = 452.0
  • Vibration sensorMQTT
    {"vib_mm_s": 2.8}
  • Maintenance systemREST API
    {"last_service": "2026-08-24"}

Pump P-03

Digital Block: Pump

  • Suction press.3.76 barIEC 104
  • Discharge press.9.48 barIEC 104
  • Motor power95.0 kWModbus
  • Flow452 m³/hS7
  • Vibration2.8 mm/sMQTT
  • Last service24 Aug 2026REST
  • Efficiency76 %calculated
  • Running hours16,813 haggregated
  • Cavitation riskLowAI

In context

ISA-95 or your own hierarchy

  • SiteSite 1
  • AreaPump station A
  • AssetP-01
  • AssetP-02
  • AssetP-03
  • AreaPump station B
  • AssetP-04

Every pump is an instance of the block: edit it once, and all of them follow.

Raw data

Scattered data sources

  • Unit PLCModbus TCP
    40011 = 128 40015 = 342
  • Field RTUDNP3
    AI 12 = 128.4
  • Flow computerOPC UA
    StdFlow = 65.0
  • Vibration monitorMQTT
    {"vib_um": 31}
  • Maintenance systemREST API
    {"last_overhaul": "2025-11-02"}

Compressor K-103

Digital Block: Gas compressor

  • Suction press.12.8 barModbus
  • Discharge press.34.2 barModbus
  • Discharge temp.128.4 °CDNP3
  • Gas flow65 MMSCFDOPC UA
  • Shaft vibration31 µmMQTT
  • Last overhaul2 Nov 2025REST
  • Pressure ratio2.6calculated
  • Polytropic eff.78 %calculated
  • Bearing anomalyDetectedAI

In context

ISA-95 or your own hierarchy

  • SiteGas plant 1
  • AreaTrain A
  • AssetK-101
  • AssetK-102
  • AssetK-103
  • AreaTrain B
  • AssetK-201

Every compressor is an instance of the block: edit it once, and all of them follow.

Engineers build blocks in Stream Explorer, from a script or through the REST API. Values shown are illustrative.

Proven at scale

A million updates a second.

2M
tags on one server
1M
updates per second
51%
peak CPU at full load

Test machine: one server, 10-core CPU (16 threads), 32 GB RAM

Stream Gateway vs leading platforms · updates per second, one server

  • Vendor A 20K
  • Vendor B 100K
  • Vendor C 150K
  • Stream Gateway 1M

Witnessed and verified by an independent testing entity. Request the test report ›

Cybersecurity

Certified to IEC 62443.

Every Stream product is built under a certified secure development lifecycle.

Request the certificates
  • IEC 62443-4-1

    Secure development lifecycle

    How we design, build and maintain every Stream product.

    Certificate CER-26-11-0001

  • IEC 62443-4-2

    Security requirements for IACS components

    The Stream software platform, version 5.0.

    Certificate CER-26-11-0002

Deployment

One product. Two ways to run it.

Enterprise and cloud

  • SCADA
  • MQTT broker
  • Cloud

Stream Gateway

At the edge · industrial PC or small server

Store and forward
  • PLC
  • RTU
  • Meter
  • Relay

On site

At the edge

Run it as an edge connector.

Install it next to the devices. It reads them natively and forwards clean data wherever it is needed.

  • Native drivers, close to the devices
  • Store and forward when the link drops
  • Publishes to SCADA, MQTT, OPC UA, REST or the cloud

As a platform

Run it as a platform for every site.

One central Stream Gateway concentrates every site into one model, with history, alarms and one API for every IT system.

  • Many sites, one asset model
  • History and alarms in one place
  • Scales out: add gateways, servers or database nodes
  • Site 1

    Edge gateway

  • Site 2

    Edge gateway

  • Site 3

    PLCs and RTUs

Stream Gateway

As a platform

  • One model
  • History
  • Alarms
  • APIs
  • ERP
  • MES
  • Historians
  • Analytics and AI

Customer stories

OT NETWORK IT NETWORK Powerplant Stream Gateway ONE WAY Hardware data diode Stream Gateway Billingsystem Data crosses one way. Nothing comes back. OT NETWORK IT NETWORK Power plant Stream Gateway Hardware data diode ONE WAY Stream Gateway Billing system Data crosses one way. Nothing comes back.
AramcoCustomer story

Power plant to billing. One way only.

At Aramco Jafurah, two Stream Gateway Software instances sit on either side of a hardware diode.

More customer stories

  • Dhahran

    Water and irrigation, into the IoT platform

  • Modon

    Utilities SCADA, into the Smart City Platform

  • MEWA

    Drillers over RUPTELA, published over MQTT

  • MISK

    Water, irrigation and smart city, both ways

  • SABIC

    Wearables and the IIoT Central Platform

Book a demo meeting.

30 minutes, online. Choose what you want to see, and we show it working on systems like yours.

  • A live walkthrough of the products you pick
  • Answers on drivers, integration and security